MS/MSN

APPLICATION:

  • Jacket cooling fresh water pump
  • Sea water service pump
  • Others

FEATURES:

  • Hydraulic impeller designed based on CFD
  • High efficiency, low NPSH & nois
  • Space coupling type utilized for easy dismantling of the motor & piping and easy repair
  • Shaft Sealing : M/Seal or gland packing type

SPECIFICATION AND SERVICE RAGES:

  • Capacities: 30 ~1,400m/hr
  • Heads: 20 ~ 60m
  • Design pressures: 10gf/cmG(142 PSIG)
  • Impeller type: Closed, single suction
  • Temperature range: 0 ~ 90C

MD/MDN

APPLICATION:

  • Cooling sea water pump
  • Cooling fresh water pump
  • Central cooling fresh water pump
  • Ballast pump
  • Inert gas cooling sea water pump
  • Turbo generator condenser cooling water pump
  • Others

FEATURES:

  • Hydraulic impeller designed based on CFD
  • High efficiency, low NPSHre & noise
  • pace coupling type utilized for easy dismantling of the motor & piping and easy repair
  • Shaft Sealing : M/Seal or gland packing type

SPECIFICATION AND SERVICE RAGES:

  • Capacities : 400 ~ 3,000m/hr
  • Heads : 8 ~ 45m
  • Design pressures : 10kgf/cmG(142 PSIG)
  • Impeller type : Closed, double suction
  • Temperature range : 0 ~ 90C

MT

APPLICATION:

  • Main lub
  • Oil pump

FEATURES:

  • Upper bearing utilizes self lubrication method so a separate lubrication is unnecessary
  • Designed to prevent loosening of the impeller's nuts against reverse rotation
  • Long term stable operation
  • Pipe depth may be adjusted flexibly as requested by the user

SPECIFICATION AND SERVICE RAGES:

  • Capacities: 100 ~ 1,800 m/hr
  • Heads: 2.5 ~ 9kg/cm2
  • Impeller type: Closed, single suction
  • Temperature range: 0 ~ 90C

M2V

APPLICATION:

  • Bilge, fire & general service pump
  • Emergency fire water pump
  • Others

FEATURES:

  • Hydraulic impeller designed based on CFD
  • High efficiency, low NPSH & noise
  • Composite line bearing for lubrication

SPECIFICATION AND SERVICE RAGES:

  • Capacities: 30 ~ 400 m3/hr
  • Heads: 50m ~ 170m
  • Design pressures: 26 kgf/cmG(369 PSIG)
  • Impeller type: Closed, single suction, 2 stages
  • Temperature range : 0 ~ 90C

 

MCP

APPLICATION:

  • Fresh water pump
  • Refrigerator cooling water pump
  • Others

FEATURES:

  • Back pull-out construction allows repair to be performed without dismantling the casing and piping
  • Available for both horizontal and vertical wall mount installation
  • Replaceable type wearing rings
  • Close-coupled for compact design

SPECIFICATION AND SERVICE RAGES:

  • Capacities : 1 ~ 25 m/hr
  • Heads: 10 ~ 80 m
  • Design pressures: 10kgf/cmG(142 PSIG)
  • Impeller type : Closed, single suction
  • Temperature range : 0 ~ 90C

MCV

APPLICATION:

  • Low NSPH condensate pump
  • Condensate pump
  • Drain transfer pump
  • Others

FEATURES:

  • Hydraulic impeller designed based on CFD
  • Low NPSHre design with higher impeller inhalation
  • Space coupling type utilized for easy dismantling of the motor & piping and easy repair
  • Shaft Sealing : M/Seal or gland packing type

SPECIFICATION AND SERVICE RAGES:

  • Capacities : 30 ~ 150m/hr
  • Heads: 15 ~ 35m
  • Design pressures : 7kgf/㎠G (100 PSIG)
  • Impeller type : Closed, single suction
  • Temperature range : 0 ~ 90℃

 

MES

APPLICATION:

  • Air conditioning ref. cooling water pump
  • Refrigerator cooling water pump
  • Miscellaneous cooling water pump
  • Fresh water generator ejector pump
  • Others

FEATURES:

  • Back pull-out construction allows repair to be performed without dismantling the casing and piping
  • Minimizes maintenance cost
  • Available for both horizontal and vertical wall mount installation
  • Replaceable type wearing rings
  • Close-coupled for compact design

SPECIFICATION AND SERVICE RAGES:

  • Capacities: 2 ~ 1,500m/hr
  • Heads: 4 ~ 80m
  • Design pressures: 10kgf/cmG (142 PSIG)
  • Impeller type: Closed, single suction
  • Temperature range: 0 ~ 90C

MTM

APPLICATION:

  • Boiler feed water pump
  • Others

FEATURES:

  • Casing is separated in a vertically split method
  • Realize high efficiency through single suction, multi-stage impeller and optimal hydro design
  • hydraulic and efficiency
  • Stuffing box is designed to withstand high pressure
  • Seal area is provided for various M/Seal utilization

SPECIFICATION AND SERVICE RAGES:

  • Capacities: 2 ~ 500m/hr
  • Heads: 5 ~ 200m
  • Design pressures: 40kgf/cmG (569 PSIG)
  • Impeller type: Closed, single suction, multi-stage
  • Temperature range: 0 ~ 90C

MV/MVN

APPLICATION:

  • Fire and general service pump
  • Bilge and ballast pump
  • Emergency fire pump
  • Others

FEATURES:

  • Hydraulic impeller designed based on CFD
  • High efficiency, low NPSHre & noise
  • Composite line bearing for lubrication

SPECIFICATION AND SERVICE RAGES:

  • Capacities: 20 ~ 350m/hr
  • Heads: 50 ~ 130m
  • Design pressures : 20kgf/cmG (284 PSIG)
  • Impeller type : Closed, single suction
  • Temperature range: 0 ~ 90C

MVF

APPLICATION:

  • Fire and general service pump
  • Bilge and ballast pump
  • Others

FEATURES:

  • Hand level type for impeller's series and parallel mode conversion
  • Hydraulic impeller designed based on CFD
  • High efficiency, low NPSHre & noise
  • Composite line bearing for lubrication

SPECIFICATION AND SERVICE RAGES:

  • Capacities : 45 ~ 500 m/hr
  • Heads : 20 ~ 120 m
  • Design pressures : 15kgf/cmG(213 PSIG)
  • Impeller type : Closed, Single Suction
  • Temperature range : 0 ~ 90C